色九色九色久中文字幕无码_日本人妖一区二区_久久久久亚洲av片无码观看_亚洲性色AV无码久久精品色欲

Bearing electric erosion
Service support - Product "Three Guarantees service" - Common fault handling

The causes of motor shaft voltage are generally considered as follows: external interference voltage, magnetic circuit asymmetry, etc., the specific reasons are very complex. Axial voltage will form axial current, resulting in corrosion of sliding bearings and rolling bearings. When bearing electroerosion occurs, the following problems are mainly checked and dealt with:

 

1) The insulation layer of the inner ring or outer ring of the insulating rolling bearing is damaged;

 

Solution: Replace the new insulated bearing

 

2) Insulation layer damage between rolling bearings and other metal parts;

 

Solution: Repair the insulation layer and measure the insulation resistance of the insulation layer to a value greater than 0.5M ω

 

3) Insulation damage at the ball belt of the bearing seat of the end cover type sliding bearing; Whether the insulation layer under the seat type sliding bearing is damp, whether the outer insulation layer is clean, etc.

 

Solution: Repair the insulation layer and measure the insulation resistance of the insulation layer to a value greater than 0.5M ω

 

4) Insulation damage of the temperature measuring rod of the end cover type sliding bearing thermometer, resulting in short connection between the bearing bush and the external; The temperature measuring line or the inlet and return oil pipe of the pedestal plain bearing is not insulated, resulting in the short connection between the bearing seat and the external.

 

Solution: repair the insulation layer of the thermometer thermometer rod; Avoid the metal protective pipe outside the temperature measurement line and the bearing seat overlapping; Check the incoming and return pipelines and repair the damaged insulation measures.